Bauphysikalische Grundlagen
AS-5 Bewertete Trittschallminderung
<u>Tabelle AS-5a:</u> Bewertete Trittschallminderung einiger gebräuchlicher Fußbodenbeläge auf Massivdecken
<table border=1 cellpadding="8" cellspacing="0"><tr><td>Weichfedernder Belag</td><td>Trägerschicht/Unterschicht</td><td>Dicke [mm]</td><td>ΔL<sub>w,R</sub> [dB]</td></tr><tr><td rowspan=2>Gummibelag</td><td>keine</td><td>3...4</td><td>9...13</td></tr><tr><td>Porengummi</td><td>5</td><td>24</td></tr><tr><td>Korkparkett</td><td>keine</td><td>6</td><td>15</td></tr><tr><td rowspan=4>Linoleum</td><td>keine</td><td>2,5</td><td>7</td></tr><tr><td>Filzpappe</td><td> </td><td>14</td></tr><tr><td>Korkment</td><td>2</td><td>15</td></tr><tr><td>poröse Holzfaserplatte</td><td>5</td><td>16</td></tr><tr><td>Nadelfilz</td><td>keine</td><td>5</td><td>17...22</td></tr><tr><td>PVC</td><td>keine</td><td>1,5...3,6</td><td>3...11</td></tr><tr><td rowspan=4>PVC-Verbundbelag</td><td>genadelter Jutefilz</td><td rowspan=4>ca. 5...8</td><td>13</td></tr><tr><td>Korkment</td><td>16</td></tr><tr><td>Schaumstoff</td><td>16</td></tr><tr><td>Synthesefaser-Vliesstoff</td><td>13</td></tr><tr><td>Sisal-/Kokosfaser-Läufer</td><td>keine</td><td>4</td><td>17...22</td></tr><tr><td rowspan=6>Teppich (aus Polyamid, Polypropylen,<br>Polyacrynitrit, Polyester, Wolle <br>und anderen Mischungen)</td><td rowspan=3>Unterseite geschäumt</td><td>4</td><td>19</td></tr><tr><td>6</td><td>24</td></tr><tr><td>6</td><td>28</td></tr><tr><td rowspan=3>Unterseite ungeschäumt</td><td>4</td><td>19</td</tr><tr><td>6</td><td>21</td></tr><tr><td>8</td><td>24</td></tr><tr><td>Verlours-Teppich</td><td>Waffelrücken</td><td>12</td><td>26</td></tr></table>
<u>Tabelle AS-5b:</u> Bewertete Trittschallminderung von schwimmenden Estrichen auf Massivdecken
<table border=1 cellspacing= "0" cellpadding="8"><tr><td> </td><td> </td><td colspan="2" align="center">ΔL<sub>w,R</sub> [dB]</td></tr><tr><td align="center">Deckenauflagen</td><td align="center">dynamische Steifig-<p>keiten der Dämmschicht <p>[MN/m³]</td><td align="center">mit hartem <p>Bodenbelag</td><td align="center">mit weichfederndem <p>Bodenbelag<p>ΔL<sub>w,R</sub></td></tr><tr><td align="center" rowspan="6">Gussasphaltestrich<p>m' ≥ 45 kg/m²</td><td align="center"><50</td><td align="center">20</td><td align="center">20</td></tr><tr><td align="center"><40</td><td align="center">22</td><td align="center">22</td></tr><tr><td align="center"><30</td><td align="center">24</td><td align="center">24</td></tr><tr><td align="center"><20</td><td align="center">26</td><td align="center">26</td></tr><tr><td align="center"><15</td><td align="center">27</td><td align="center">29</td></tr><tr><td align="center"><10</td><td align="center">29</td><td align="center">32</td></tr><td align="center" rowspan="6">Zementestrich<p>m' ≥ 70 kg/m²</td><td align="center"><50</td><td align="center">22</td><td align="center">23</td></tr><tr><td align="center"><40</td><td align="center">24</td><td align="center">25</td></tr><tr><td align="center"><30</td><td align="center">26</td><td align="center">27</td></tr><tr><td align="center"><20</td><td align="center">28</td><td align="center">30</td></tr><tr><td align="center"><15</td><td align="center">29</td><td align="center">33</td></tr><tr><td align="center"><10</td><td align="center">30</td><td align="center">34</td></tr></table>
<table border="0" cellpadding="0" cellspacing="0"><tr><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Index.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Baukonstruktionen.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Objektbeispiele.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Grundlagen.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Glossar.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Rechentools.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Fotogalerie.html" target="_top">
</a></td><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Planunterlagen.html" target="_top">
</a><td><td colspan="3"><a href="http://www.bauphysikalische-altbaumodernisierung.de/Index.html" target="_top"></a></td></tr><tr><td><a href="http://www.bauphysikalische-altbaumodernisierung.de/Index.html" target="_top">
</a></td></tr></table>